Description
Specifications
| Operating principle: | NDIR(dual channel non-dispersive Infrared) technology MEMS (Microelectronic Mechanical Systems) Measurement target: CO2,CO/HC/H2,Temperature |
| Measurement range: | CO:0ppm~1000ppm(Display up to 3Kppm) CO2:0ppm~10000ppm(Display up to 60Kppm) Temperature:-40℃~120℃ |
| Resolution: | CO2/CO/HC/H2:1ppm Temperature:0.1℃ |
| Accuracy: | CO2:±(50ppm+5%reading) CO:±40ppm or ±30% max reading Temperature:±2℃ |
| Response time | T90≤15s |
| Working temperature | -40~+85℃,0-95%RH (non-condensing) |
| Storage temperature | -40~+95℃,0-95%RH (non-condensing) |
| Working pressure | 80kPa~120kPa |
| Power supply | 9~16 VDC, standard voltage 12 VDC |
| Working current | ≤100mA @12VDC |
| Low power consumption mode | ≤50mA @12VDC |
| Standby current | ≤100μA |
| Communication | CAN |
| IP grade | IP54 |
| Dimension | 77*38*20 (mm) |