Description
Specifications
| Accuracy | +/-2% of reading |
| Response Time (t90) | <60s |
| Measurement Range | 0 to 10,000ppm |
| Resolution | 0.5ppm |
| Sensitivity | 1.5nA to 3.0nA / ppm |
| Temperature Range | -4˚F to 122˚F (-20˚C to 50˚C) |
| Humidity Range | 5 to 99% RH |
| Dimensions | diameter 13.8mm x 50.75mm length |
| Weight | 12g |
| Life Expectancy | 8+ years |
Operating Principle

ECO-5011 is a fuel cell type gas sensor. Carbon Monoxide and oxygen undergo a redox reaction on the work electrode and the counter electrode which then releases a current signal that can be measured.
The generated current is proportional to the carbon monoxide concentration.




Reviews