PM2016 Laser Scattering Particulate Matter Sensor

GRIMM Three-Channel Output and Real-Time Particle Counting Output
Direct Measurement of Suspended Particles
Direct Replacement of Sensirion SPS30

Features

  • Three-Channel Output - PM1.0, PM2.5, PM10
  • Particle Counting Output - 0.3µm, 0.5µm, 1.0µm, 2.5µm, 5.0µm, 10µm
  • Anti-Dust design ensures accuracy throughout the installed life
  • Auto Particle Identification allows the sensor to "switch" between calibration algorithms based on changing application needs
  • Constant speed fan and constant power diode maintain measurement accuracy and stability

Description

Specifications

Measurement Particle Range 0.3µm to 10µm
Measurement Range 0 to 1,000µg/m3
Resolution 1µg/m3
Accuracy PM1.0 & PM2.5: 0 to 100µg/m3, +/-10µg/m3

PM1.0 & PM2.5: 101 to 500µg/m3, +/-10% of reading

PM10: 0 to 100µg/m3, +/-25µg/m3

PM10: 101 to 500µg/m3, +/-25% of reading

Temperature Range ’14˚F to 140˚F (-10˚C to 60˚C)
Humidity Range ‘0 to 95% RH
Supply Voltage 5VDC +/-0.1VDC
Supply Current <80mA
Communication Interfaces  UART & I2C
Dimensions 40.7mm x 40.7mm x 12.2mm
Weight 26.5g
Life Expectancy 128,000 hours (14.6 years), continuous operation

Reviews

There are no reviews yet.

Be the first to review “PM2016 Laser Scattering Particulate Matter Sensor”

Your email address will not be published. Required fields are marked *